Model TR30

Resistance thermometer

Compact design

Selected documents
Sales contact Questions? Find a contact in your vicinity.

Applications of the resistance thermometer

  • Machine building, plant and vessel construction
  • Propulsion technology, hydraulics
  • General applications

Special features of the resistance thermometer

  • Measuring ranges from -50 ... +250 °C (-58 ... +482 °F), accuracy class per DIN EN 60751
  • TR30-W: integrated transmitter, programmable and able to be calibrated via software
  • Electrical connection via DIN angular connector or circular connector
  • Process connection and sensor tube from stainless steel
  • Explosion-protected versions Ex i

Description of the resistance thermometer

Resistance thermometers of this series are used as universal thermometers for the measurement of liquid and gaseous media.

They can be used for pressures up to 40 bar (special designs to 400 bar dependent on insertion length and diameter). All electrical components are protected against splashed water and are designed to withstand vibration.

The TR30 resistance thermometer consists of a sensor tube, which can be fixed into the process using a permanentlywelded threaded connection or a compression fitting. A version with no process connection is also available. The electrical connection is made via a DIN angular connector or an M12 x 1 circular connector.

Output signal Pt100
The model TR30-P resistance thermometer is available with a direct Pt100 signal. An intrinsically safe variant can be supplied as an option. 

Output signal 4 ... 20 mA
In the model TR30-W resistance thermometer, a softwareprogrammable transmitter with a 4 ... 20 mA output signal is built in. Thus the measured temperature values can be transmitted safely and simply. The model TR30-W resistance thermometer is available, as an option, in an intrinsically safe variant.